3.5 INSTALLATION OF 230 V AC
An authorized installer must do the 230 V AC installation
Connection to the 230 V is made on the socket shown in Figure 10.
The connection to the 230 V circuit is made in the 3-plug socket on the
power box. Screws do the plug connection in the socket. Be sure that the
cable is properly and safely connected in the socket and that the cable is
fixed with the cable clamp.
For safety reasons a RCCB and a two-pole fuse 16 A must be installed on
the 230 V AC circuit.
If an external power source is required a two-pole three position manual
switch with a 0-position must be used to separate the external power from
the power delivered by Travel Power.
If an automatic switching device is used the Travel Power must be
connected to the zero position and external power to the active side. The
switching device must have a terminal distance not less than 3 mm.
Power is never to be connected from an external source to the 230 V
outlet on Travel Power. This will cause damage to Travel Power.
Figure 10. Connection to the Power box
Socket for 230 V connection
From the generator
230 V cable