Dometic TCW1152 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Nie Dometic TCW1152. Dometic TCW1152 User Manual [fr] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 27
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
820 41 72 24
USER
USER
s MANU
s MANU
AL -
AL -
NO
NO
TICE DUTILIS
TICE DUTILIS
A
A
TION -
TION -
MANU
MANU
AL DEL USU
AL DEL USU
ARIO
ARIO
TCW 1152
ICE LINING REFRIGERATOR FREEZER
GB
REFRIGERATEUR / CONGELATEUR
A PAROI REFRIGERANTE - ILR
FRIGORIFICO/CONGELADOR
REVESTIDO DE HIELO
F
E
Przeglądanie stron 0
1 2 3 4 5 6 ... 26 27

Podsumowanie treści

Strona 1 - TCW 1152

820 41 72 24USERUSERs MANUs MANUAL - AL - NONOTICE DUTILISTICE DUTILISAATION -TION -MANUMANUAL DEL USUAL DEL USUARIOARIOTCW 1152ICE LINING REFRIGE

Strona 2 - USER MANUAL

10Fill the tube with water leaving a space of about 10 cmUNFILLED at the top (fig. 13). Replace the plug.(Examine for any leakage of water. Leaking tu

Strona 3

115.Lift up and take out the plastic floors of the ILR (fig.15).The floors can be lifted by using the holes of thefloors.6.Fill the ice-packs with cle

Strona 4 - 1. GENERAL INFORMATION

128.Make sure that the above actions 5, 6, and 7 hasbeen done for the smaller chamber, too. NOW THEILR IS READY TO STARTCheck the required function of

Strona 5 - 2. INSTALLATION

133.Connect the plug of the power supply cord to the wallsocket and put ON the switch, if any. The `yellow'indicator light on the right hand side

Strona 6

147.The control thermostat for adjustment of the LR to therecommended temperature is located between 2indicator lamps on the front panel. This has set

Strona 7

159.When the temperature inside the ILR is observed tobe steady for several hours within +4° to +8°C onlythen the vaccines to be preserved should betr

Strona 8

1612.When fresh vaccines are stored in the ILR, the cabinettemperature may go up initially but should fall andcome to the required range after few hou

Strona 9

173.Examine the display plate on the lid. If it displays`Refrigerator' function, slide it out from its frame,reverse and put it back to display `

Strona 10 - 3. PREPARATIONS

185. TO USE A FREEZERFig. 30.6.Allow the ILR to run. The temperature inside thecabinet will be indicated on the thermometer on thefront side. Observe

Strona 11

199.Water in the tubes will be frozen fully within 1-3 days,depending on different conditions (fig. 31 )10.Put one layer of ice-packs (filled with wat

Strona 12 - 4. TO USE A REFRIGERATOR

USER MANUAL2ICE LINING REFRIGERATOR FREEZERHandleRubber gasketIce lining,plastic tubesData labelThermometer85010501465CompressorcompartmentPilot lamp

Strona 13

2012.After storing the vaccines, keep the lid properly closedand locked (fig. 33)`T0 USE ILR PRESENTLY RUNNINGAS `FREEZER' TO WORK AS`REFRIGERATO

Strona 14

21DEFROSTING & CLEANINGPROCEDURE1.Switch OFF the power supply to the ILR and removethe plug of its power supply cord from the wall socket.2.Prepar

Strona 15

225.Open the drainage plug at the bottom, outside thecabinet.Keep a suitable container under the drain hose tocollect the defrost water (fig. 34)6.Kee

Strona 16 - 5. TO USE A FREEZER

237.Clean the ILR carefully as below,a) Wash all parts inside the cabinet with warm waterand mild detergent.b) Clean the lid and the lid seal (gasket)

Strona 17 - TO USE A FREEZER

24DAILY1. Take temperature readings from the thermometersand note down the temperature and the time ofreading.Keep the temperature records systematica

Strona 18

25IMPORTANT:When an ILR is found to be not working at all or notworking properly, see that the vaccine temperature iswithin the recommended limits. Do

Strona 19

264.If the compressor is observed to be runningcontinuously but no cooling is attained - this may bedue to leakage of refrigerant gas from the system

Strona 20

27IF THE ILR IS TO BE SHUT DOWN FORTRANSPORTATION ETC.Disconnect the power-supply plug from socketAllow the ice in the liner tuber (if any) to melt an

Strona 21 - 6. DEFROSTING & CLEANING

1. GENERAL INFORMATION...page 42. INSTALLATION ...

Strona 22

THE ILROne of the most important links in the cold-chain is IceLining Refrigerator (ILR). This is a unit which operateson the principle of vapour comp

Strona 23

Check the manufacturer's plate, at the back of the ILRand make sure that the ILR has correct voltage forlocal supply, i.e. 1 15 or 230 volts (fig

Strona 24

3.EXAMINE the compressor compartment (fig. 3;Check carefully for any damage, dislocation orlooseness etc. of the components, specially atlocations A,

Strona 25 - 8. TROUBLE SHOOTING

LOCATION B (fig 5)Check that the incoming electrical connections of thepower supply cord to the terminal strip are tight.LOCATION C (fig. 6)Check that

Strona 26

84.Refit side cover of the compressor compartment intoposition refixing the screws holding the side cover (fig.8)6.INSTALL firmly the ILR on a levelfl

Strona 27 - 9. SHUTTING DOWN

98.Connect the leads of the power supply cord to asuitable 3-pin plug as shown below (fig. 10)Lead of cord Pin of plug Green/yellow Earth Blue Neutral

Komentarze do niniejszej Instrukcji

Brak uwag