6
When using battery operation, the cooling performance is not thermostatically regulated, i.e. knob (A)
is ineffective.
When knob (A) is ineffective or if the temperature is unnecessarily too low:
Turn off unit
Pull out plug from socket.
8.Liquid gas operation
Do not use any additional form of energy (mains/battery). The unit must not be connected to town or
natural gas pipelines. It is only suitable for use with propane/butane gas (e.g. Calor Gas, Camping
Gaz, Caravangas, etc).
The specified gas-connection pressure is given in mbar on the type plate (see back of appliance). It
is important that a non adjustable pressure-regulator is used to reduce the pressure in the gas cylinder
to the operating pressure specified on the rating-plate, no other pressure may be used.
Needle valve operated gas control taps are NOT suitable for use with this appliance and must
not be used as a substitute for a pressure regulator.
9.Connecting the cooling unit to the gas cylinder
(The following instructions refer in the main to coolers manufactured for the United Kingdom. For other
countries please refer to your supplier).
Always connect in the following sequence:
GAS BOTTLE
→→
PRESSURE-REGULATOR
→→
APPLIANCE.
To connect the appliance to the pressure-regulator an APPROVED GAS TUBING should be used. This should
be minimum in length - have an inside dimension of 8mm and be marked BS3212/2/8.
The pressure-regulator must be compatible for Butane 11 in (28 mbar) or for Propane (37 mbar).
To connect the pressure-regulator to the gas bottle, the valve of the gas bottle must be closed. After connecting
the pressure regulator to the bottle by screwing, connect the two ends of the tubing to the nipples and secure
them with the two hose clipse.
When fitting the connection to the gas inlet of the appliance, hold counterpart to avoid straining and
possibly damaging.
The gas bottle must only be used in an upright position and particular care must be taken every time
the appliance is connected to the gas bottle to ensure that there are no leaks, that the gas pipe (rubber
hose) is not under tension or kinked, and that it is not in contact with hot surfaces.
The connection pipe and gas bottle should always be located in positions where they will not be
tripped over or otherwise inadvertently disturbed.
Before attempting to light the burner, every time after connection, turn on the gas at the bottle and
check the gas connections for leaks by applying a soap and water solution over them and watching
for bubbles, which would indicate a leak.
After testing dry off traces of detergent.
For your safety
Do not check for leaks with a naked flame!
Do not smoke while checking for leaks!
Komentarze do niniejszej Instrukcji