REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION.
RM2301 RM2401
RM2501
RM2601 RM2801
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don’t touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the vi-
cinity of this or any other appliance.
Page
Installation
7-10
Instructions for use
11-12
Gas eqiupment
13
Electric equipment
13
Maintenance
14
Fault tracing
14
Door panel
last page
]/-TGxq
quality leisure line products
Corporate OffIce
2320
lndustrial
Parkway
Elkhart,
IN 46515
USA
SALES OFFICES
Zone I
Elkhart, IN 46515
2320
lndustrial
Pkwy.
Phone:
219-295-5228
Zone Ill
City
of Industry. CA 91746
14441
BoneIli
Street
Phone: 818-968-9431
CANADA
Dometic
Distribution
Inc.
866 Langs
Drive
Cambridge,
Ontario
N3H
2N7
Canada
Phone: 519-653-4390
Zone II
Arlington,
TX 76011
2920 Avenue “E” East
Phone:
817-649-5726
820 45
52-00/7
8204552007
Przeglądanie stron 0
1 2 3 4 5 6 7 8 9 10

Podsumowanie treści

Strona 1 - 8204552007

REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION.RM2301 RM2401RM2501RM2601 RM2801FOR YOUR SAFETYIf you smell gas:1. Open windows.2. Don’t touch electric

Strona 2 - INSTALLATION

INSTRUCTIONS FOR MOUNTING THE DOOR PANELINSTRUCTIONS FOR MOUNTINGTHE DOOR PANELThe refrigerator is normally delivered without doorpanel(s). Before sta

Strona 3 - THE REFRIGERATOR

INSTALLATIONGENERAL INSTRUCTIONSThis appliance is designed for storage of foods and stor-age of frozen foods and making ice.The refrigerators outlined

Strona 4 - VENTILATION HEIGHTS

SPECIAL HINTSNote. Do not install the appliance directly on carpeting.Carpeting must be protected by a metal or wood panelbeneath the appliance which

Strona 5 - CLEARANCES

CERTIFIED INSTALLATION#Certified installations require one roof vent and one lower sidevent or as optional one upper vent and one lower side ventThe t

Strona 6 - INSTRUCTIONS FOR USE

CLEARANCESMinimum clearances in inches to combustible materials areG: Top 0K: Side 0L: Bottom 0M: Rear 1N: See example belowClearance M between the re

Strona 7

INSTRUCTIONS FOR USEHOW TO START THE REFRIGERATORLevelingIn the boiler ammonia vapor is distilled from an am-monia-water mixture and carried to the fi

Strona 8

DefrostingShut off the refrigerator.tmpty the retrigerator leaving the drip tray under thefinned evaporator and the cabinet and freezer doorsopen. If

Strona 9 - ODOR FROM FUMES

GAS EQUIPMENTFlue Top and BaffleThe flue baffle is suspended from the top, and must bein position in the central tube of the cooling unit.The Flame Fa

Strona 10

PERIODIC MAINTENANCENOTE. Before working on the refrigerator make surethat 120 V A.C and optional 12 V D.C leads are di-sconnected.Shut off gas valve.