The freezer should be adjusted to be level from left
to right as well as from the front to the back. Place
the spirit level supplied, on the bottom of the tank of
the freezer to confirm whether it is level. A level
floor will ensure that the fridge is level.
The freezer should always be kept away from
inflammable materials.
LP GAS CONNECTION
The freezer is designed for operation on LP gas,
the pressure of which must be as indicated in the
table below. Check that this is stated on the Data
plate.
Category Type of gas Pressure
I
3 (BP 30)
Butane/Propane
(50/50)
28 30 mbar
I
3+ (28-30/37)
Butane 29 mbar
Propane 37 mbar
The LP Gas inlet connection of the freezer consists
of an 8mm gas supply pipe to take a compression
fitting. This is located at the back of the freezer. The
freezer should be installed in accordance with the
regulations in force
The freezer is not designed for operation on
town gas or natural gas.
CAUTION! CHECK THAT THE GAS SUPPLIED
TO THE FREEZER IS AT THE CORRECT
PRESSURE. SEE THE REGULATOR ON THE LP
GAS CONTAINER.
The gas installation should only be carried out by a
person experienced in gas fittings
On completion of installation, the system must
be pressure tested by a qualified person.
ELECTRICAL CONNECTION
The electrical installation must be carried out in a
proper and durable manner, taking into account all
relevant regulations and codes of practice.
For connection to a mains electrical supply, the
freezer has a 3core mains lead which is intended
for connection to a properly earthed plug and
socket outlet.
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follow:
- the wire which is coloured Green and Yellow
must be connected to the terminal in the plug
which is marked with the letter E or by the
Symbol , or coloured Green or Green
and Yellow,
- the wire which is coloured Blue must be
connected to the terminal which is marked
with the letter N or coloured Black,
- the wire which is coloured Brown must be
connected to the terminal which is marked
with the letter L or coloured Red.
WARNING- THIS APPLIANCE MUST BE
EARTHED
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or a similarly qualified person, in order
to avoid a hazard.
IMPORTANT
The wires in this mains lead are coloured in
accordance with the following code:
- green/yellow earth
- blue neutral
- brown live
Electrical leads must be routed and secured
so that they cannot come into contact with
hot or sharp parts of the freezer.