4.
With a pair of pliers unfold the lug holding the lid of the boiler
casing and open the lid
5.
6.
7.
Remove some insulation wool so that the heater is accessible
Turn and lift the heater out of its pocket
Fit the new heater into the pocket and pull on the hose around
the leads
8.
Connect the leads and put on the plastic cover
9.
Reset the insulation and close the lid of the boiler casing
The Switch
The electric control also comprises an on-off switch operated by
the selector knob at the front panel. The switch has two “on”-
positions, one for 120 Volts A C (ELEC.) and one for 12 Volts D C
operation.
The Thermostat
The electric thermostat is combined with the gas ther-
mostat and is thus operated by the knob (B) at the front
panel. The temperature in the refrigerator can be
regulated by turning the thermostat knob. Although the
exact setting is not critical choose a setting at which the
frost that gradually forms on the cooling evaporator is
just maintained in dry condition.
It will be necessary to turn the thermostat knob closer to MAX
when the ambient temperature becomes higher or the load
unusually heavy.
If less cooling is required a lower setting should be chosen.
PERIODIC MAINTENANCE
NOTE. Before working on the refrigerator make sure that 120 V
A. C. and optional 12 V D. C. leads are disconnected.
Shutoff gas valve.
The Burner and the Burner Jet
The color of the flame should be clear blue over the slots
of the burner.
Once or twice a year depending on use, it is necessary to
clean and adjust the burner assembly. Proceed as
follows:
1 Loosen screw and remove cover plate for burner
housing.
2 Disconnect lighter cable from the electrode.
3 Loosen burner fixing screw and withdraw burner.
4 Clean burner tube with a brush. Blow with-
compressed air.
5 Unscrew jet and clean with alcohol. Blow with com-
pressed air. Never use a needle or similar instrument
to clean jet.
6 Reassemble.
7 Be careful that the end of the burner fits into the
slot on the bracket.
The slots of the burner must be centrally located under
the boiler tube.
The Electrode
For a proper ignition function it is necessary to keep the electrode
insulation dry and free from dirt. The gap between burner tube
and electrode shall be max.
3/16”
(5 mm) and min.
1/8"
(3 mm).
WARNING
If the refrigerator is used intermittently it should be checked at
least once a year.
It is important to keep the appliance area clear and free from
combustible materials, gasoline and other flammable vapors
and liquides. Check the venting system. The flow of combustion
and ventilating air must not be obstructed.
Check the flue baffle that it is clean and reasonably free from
soot. Heavy soot formation indicates improper functioning of the
burner. Clean baffle and flue. Further, clean cooling unit and floor
under refrigerator.
The entire gas installation should be checked for leaks at
intervals. Test all pipe connections with a soap and water
solution, not with an open flame.
NOTE:
Any service of the gas controls, with exception of
above mentioned replacement, maintenance and clean-
ing operations must be performed by an authorized ser-
vice center only.
Note: Avoid water spraying through the
refrigerators vents while washing your RV.
FAULT TRACING
The refrigerator does not freeze
satisfactorily
Causes and remedies
a)
b)
c)
d)
e)
f)
g)
h)
i)
j)
k)
Jet orifice clogged. Unscrew jet and blow clear or wash in
alcohol. Do not use wire or pin to clean orifice.
Check the leveling of the refrigerator.
Flame has gone out. Remedy: 1) Gas in bottle is us-
ed up. 2) Tip of the thermocouple is not heated
enough by flame.
3) Clogged by-pass screw
-
clean or exchange it.
Air circulation around cooling unit is restricted. Be sure that
refrigerator is properly ventilated.
The evaporator is heavily coated with frost. Defrost.
Flue baffle not inserted into the central tube of the cooling
unit.
The thermostat is incorrectly used. See paragraph on ther-
mostat. In hot weather the setting should be closer to MAX
than usual.
Gauze in burner head clogged. Clean.
Burner damaged. Replace.
Burner may be dislocated. Relocate.
Wrong gas pressure at the burner. Have pressure checked at
burner and at gas bottle. Pressure at burner must not fall
below 11
”
W.G. when thermostat is set on MAX.
ODOR FROM FUMES
Causes and remedies
The flame touches side of the boiler due to dislocation of the
burner. Relocate. Burner dislocation may also cause smoke
and discoloring of walls and ceiling.
Burner damaged. Replace.
The flame touches flue baffle. Remedy: 1) Burner damaged.
Replace. 2) Flue baffle too low. Correct the position of the
baffle.
The flue tube is dirty. Clean flue as follows: Cover burner and
jet. Remove flue top and baffle. Clean flue with special flue
brush. Clean baffle before putting back in place.
All the above instructions are to be followed closely. The
refrigerator is quality-guaranteed. However, we are not responsi-
ble for any failures caused by improper adjustments and
unfavorable installation conditions. Contact service point or dis-
tributor service dept. for assistance.
Replacement Parts Suppliers: See cover.
11